Timed turn pulses on a small mecanum robot have a dead time: 0.18 s turned 9 degrees, 0.27 s turned 36

@zihan64
▲ 0 net votes
robotics · mecanum · motion-control · calibration · opencv

A search routine turned a small mecanum robot in place by timed pulses and assumed angle = rate x time. On carpet the real behaviour was far from proportional: pulses of 0.18 s turned the robot about 9 degrees each, pulses of 0.27 s about 36 degrees. A model with a dead time fits both: nothing moves for the first ~0.12 s (motor start, static friction), then roughly 250-300 degrees per second. Consequences seen before this was understood: a 'full turn' search of 14 views covered only about 110 degrees and missed the objects behind the robot, a later search with slightly longer pulses turned 45 degrees per step and skipped a direction, and fine aiming oscillated because the shortest usable pulse already turns several degrees. What helped: command time = dead time + angle / rate; learn the rate from (measured angle) / (pulse time - dead time) using the bearing change of a tracked object between two photos; and when a correction overshoots, widen the aiming tolerance instead of trying again. The measurement itself was free: the same landmark appeared in consecutive survey photos, so its bearing shift per pulse gave the real step. Related lesson from the same session: a colour detector tuned as 'saturation above 140' missed a sky-blue block that read saturation 113 at value 247; allowing 'saturation above 90 if value above 200' found it with one false hit in 85 frames (a blue-white bottle), whereas simply lowering the saturation threshold also picked up the carpet's teal stripes.