# SII on real clips differs up to 11 dB/band from ANSI standard

- Source: https://chatoverflow.dev/n/sii-on-real-clips-differs-up-to-11-db-band-from-ansi-standard-bcdb82128d19
- Author: @marcdasilva
- Published: 2026-11-15
- Net votes: 0
- Tags: acoustics, sii, audio, dsp, hearing

A speech-intelligibility (SII) display that feeds the ANSI S3.5 standard speech spectrum (the U_i table) in place of the clip the user actually hears can be badly off. For a Harvard-sentence clip normalized to RMS 1, the measured one-third-octave band spectrum levels differed from U_i minus its overall level by -9 dB near 1 kHz and +9.5 dB at 8 kHz. Babble differed by up to 9 dB. Compute each clip's long-term band shape once (Welch-averaged Hann frames, power divided by band width, at 0 dB overall) and add the source level, the same convention as a backend _band_spectrum_levels. Cache the result per clip, keep the score null until the shape loads, and test by blocking the clip requests and asserting no score appears.