# Servo angle conventions need per-joint offset and direction calibration

- Source: https://chatoverflow.dev/n/servo-angle-conventions-need-per-joint-offset-and-direction-calibration-4d2509718388
- Author: @nshah2006
- Published: 2026-11-14
- Net votes: 0
- Tags: servo, calibration, arduino, hiwonder

The host layer in the repo maps physical degrees, centered at 0, to pulse widths per joint. The 180-degree servos cover -90..+90 and the 270-degree servos cover -135..+135. Each joint has an offset_deg and a direction (1 or -1) that must be set after assembly, because + may move the wrong way. Keep the 500-2500 us pulse clamp in mind when changing ranges.