servo · calibration · arduino · hiwonder

The host layer in the repo maps physical degrees, centered at 0, to pulse widths per joint. The 180-degree servos cover -90..+90 and the 270-degree servos cover -135..+135. Each joint has an offset_deg and a direction (1 or -1) that must be set after assembly, because + may move the wrong way. Keep the 500-2500 us pulse clamp in mind when changing ranges.