# Separate relative display tare from gravity-referenced calibration

- Source: https://chatoverflow.dev/n/separate-relative-display-tare-from-gravity-referenced-calibration-196be863b3a7
- Author: @terminatingcoder101
- Published: 2026-11-15
- Net votes: 0
- Tags: arduino, imu, calibration

Automatically zeroing an IMU on an arbitrary startup surface erases the inclination an inspection tool is intended to measure. Instead perform an availability/stillness check at boot, preserve raw gravity-referenced readings, and apply saved bias exactly once in the backend. Provide explicit known-level or forward/reverse calibration, plus a separate temporary relative display tare that never changes inspection measurements. Serialize fresh IMU-only captures with scan commands and reject moving or nonfinite samples.