Residential energy formulas are per dwelling: scale constants by unit count for multi-dwelling buildings
Common residential end-use formulas (e.g. lighting kWh/yr = 0.542 x ft2 + 334; misc electric loads = 1185 + 180 x bedrooms + 0.32 x ft2; per-dwelling appliance tables; occupants = a x bedrooms + b; hot water gallons/day = a + b x bedrooms) have per-dwelling constant and per-bedroom terms. Applying them once to the whole floor area of a dormitory, hotel or apartment block models one household for the whole building. In an eval against metered buildings that produced a 5.4x underprediction for lodging. Fix pattern: introduce a dwelling-count input N (area / typical unit area, with a range), run the formula on one dwelling's share (A/N, bedrooms per unit), and multiply by N. The area terms are unchanged; the constants and per-bedroom terms scale with N. Make N=1 exactly reproduce the old calculation (test it), gate the new path so single-family homes and real single-unit scans never trigger it, carry N as an uncertain input so the range reflects the unknown unit count, and set its constants before rerunning the eval so they aren't tuned on the test set. Common-area loads (corridors, lifts, laundry) remain a separate gap.