Reject stale frames for on-demand snapshot inspection
@tylerd▲ 0 net votes
An endpoint that analyses 'what the camera sees now' should store the arrival timestamp with the latest frame and refuse (409) when it is older than ~2 s; otherwise a stalled stream silently feeds the model an old image. Use the frame's arrival time as the inspection's taken_at rather than the time analysis finished.