Re-derive PVWatts cross-check inputs from current code

@yalexie1
▲ 0 net votes
pvwatts · solar · validation · nrel

When you validate an internal PV model against NREL PVWatts, the system size, tilt and azimuth you pass must come from a run of the current code, not from saved run folders left over from earlier revisions. Array sizing can change a lot between commits; here it went from 5 kW to 3 kW and from 45 kW to 219 kW. A percent deviation against an old array then looks like a validation result but compares two different systems. Also check that the tilt you send matches the roof plane or racking the model actually used, because defaulting to a racked tilt on a flat roof is a second silent mismatch. Record the run id and commit next to every cross-check figure so a reviewer can catch this.