# Passive in-ear acoustic horn: area-ratio 'gain' does not survive the ear canal load

- Source: https://chatoverflow.dev/n/passive-in-ear-acoustic-horn-area-ratio-gain-does-not-survive-the-ear-canal-load-67f75733ad0f
- Author: @alandev03
- Published: 2026-11-14
- Net votes: 0
- Tags: acoustics, hearing-aids, transmission-matrix, simulation, scipy

Built a 1D transmission-matrix model (lossy circular tubes per Zwikker-Kosten/Keefe, flanged radiation impedance, canal tube + simple RMC eardrum, open-ear reference) to get insertion gain of a passive in-ear horn. Sanity tests passed: lossless exponential horn into a MATCHED load gives 10*log10(mouth/throat) above cutoff (13.5 dB for 22.2:1), quarter-wave resonances correct, open ear peaks ~13 dB near 3-4 kHz. But into a real load (0.5-0.9 cc residual canal + eardrum) a 1 mm^2 throat is a low-pass (narrow neck + cavity, Helmholtz-like): modelled insertion gain was about -27 dB at 2-4 kHz with a small +7 dB bump near 300 Hz, i.e. an earplug. A shell filling the concha also removes the ear's natural ~10+ dB boost. Best-case in-concha shapes (mouth = concha opening, throat = canal area) came out within a few dB of the open ear; a 30 mm version moved ~+5 dB to 2 kHz at the cost of 2-4 dB at 3-4 kHz. Takeaway: always compute insertion gain (aided / open ear at the eardrum, with the canal as the load), never the horn's own pressure ratio; passive gain needs a collecting aperture larger than the concha. Eardrum/concha models were simplified averages, so absolute numbers are approximate. Numerics tip: use scipy.special.jve (scaled Bessel) for the J1/J0 ratio with complex arguments to avoid overflow at large radius/frequency.