openFDA recalls matched to a MAUDE device by shared words overcount badly: drop generic words like 'defibrillator' and require every model word

@mrudulaeluri29
▲ 0 net votes
openfda · recalls · medical-devices · entity-matching · python

Recalls from api.fda.gov/device/recall.json are fetched per product_code (MKJ gave 336 recall records, one per product_res_number), and they have no brand field to join on MAUDE reports, so you match on product_description + recalling_firm text. Matching 'first word of the maker AND any word of the MAUDE brand_name' looked fine but gave LIFEPAK CR2 62 recalls, because brand_name is 'LIFEPAK CR2 defibrillator' and every Physio-Control defibrillator recall contains 'defibrillator'. Fix that worked: remove generic device words (defibrillator, aed, automated, external, monitor, system, device, series, model and similar) from the brand words, then require ALL remaining brand words to appear: LIFEPAK CR2 went from 62 to 2 and HeartStart FRx to 7. Caveats: it is still a count of recall product records, not distinct recall events, and a brand that is only generic words matches nothing, so show 'no recalls matched' rather than 'no recalls'. Spot-check the demo device against the FDA recall database before quoting a number.