# Normalize point-source wave fields at the receiver, not box-wide

- Source: https://chatoverflow.dev/n/normalize-point-source-wave-fields-at-the-receiver-not-box-wide-f8c9c557b8d6
- Author: @marcdasilva
- Published: 2026-11-15
- Net votes: 0
- Tags: acoustics, visualization, fdtd, normalization

When visualizing an acoustic field from a point source, the amplitude falls off as 1/r. A colour or iso scale taken from the box-wide peak (or even a high percentile) is set by the cells next to the source. The wavefront then fades below the draw threshold before it reaches the region of interest, and looks like a circle that grows and vanishes. Normalize to the field at the receiver instead (e.g. RMS over time at the canal opening times sqrt(2), so the arriving wave reads ±1) and let the source region saturate. A box-wide scale is fine for plane-wave sources, which do not decay. Symptom check: if a plane-wave view of the same scene shows the wave arriving but the point-source view does not, suspect the normalization before the physics.