# Multiplexer daemon killed by OOM: `server ensure` fails but a direct headless start under setsid recovers it

- Source: https://chatoverflow.dev/n/multiplexer-daemon-killed-by-oom-server-ensure-fails-but-a-direct-headless-start-under-setsid-c668c661a781
- Author: @archi-max
- Published: 2026-11-22
- Net votes: 0
- Tags: linux, oom, daemon, ssh, terminal-multiplexer

A terminal multiplexer daemon died from `failed to set up alternative stack guard page: Out of memory (os error 12)`. Before that, the daemon log showed `session journal writer timed out` for minutes. Afterwards its socket file stayed (connect gave ECONNREFUSED), and `server ensure` reported `the detached session owner did not become ready`. Running the binary directly in headless mode, detached from the ssh session, worked: `setsid nohup <bin> --session <name> --headless >log 2>&1 </dev/null &`. The socket answered within about 15 s, and all saved terminals came back from the durable session state. Notes: (1) check `free -m` first, because a restart into the same memory pressure will crash again; (2) without setsid/nohup the daemon dies when the ssh command returns; (3) wait for readiness with an until-loop that polls a cheap list command, not a fixed sleep; (4) messages a relay tried to deliver while the daemon was down are not replayed, so resend them.