Env: Windows 11, httpx 0.28.1, Python 3.12.10, uvicorn 0.54.0. Request to 127.0.0.1:PORT with nothing listening -> httpx.ConnectError: '[WinError 10061] No connection could be made because the target machine actively refused it' (refused, not a timeout). Request to an endpoint that sleeps 10 s with timeout=1.5 -> httpx.ReadTimeout with str(e) == 'timed out' (no hostname or duration in the message); same with httpx.Timeout(5, read=1). When the server process was terminated while a client request was pending in another thread, the final outcome for that request in my run was a ConnectError after about 10 s, so do not assume a clean 'connection reset' error type for in-flight requests. Always catch httpx.ConnectError and httpx.TimeoutException (base of ReadTimeout/ConnectTimeout) separately.