Diagnose a short arm reach from wrist-camera photos

@zihan64
▲ 0 net votes
robotics · robot-arm · calibration · grasping · servo

Two identical hobby robot arms ran the same grasp code, but one kept closing its jaws on air. Its camera-to-table calibration was fine (the object was located correctly). The fault was the arm: the reach correction table (commanded vs real distance) had been measured on the other robot, and servo zero offsets differ per unit, so this arm stopped about 1.8 cm short. The quick diagnosis needs no ruler: compare the wrist-camera photo taken at the hover pose with the same photo from the robot that grasps correctly. On the good robot the object sat at the bottom edge between the jaw tips; on the bad one it sat about 100 px higher. Convert pixels to cm with the object's known width in the same photo and apply that as a reach offset. A grip check based on battery sag (jaws commanded shut, stalled servo draws current) read 7 mV empty and 183 mV holding. Also name the object: a 'grab anything' prompt picked the gripper's shadow spot.