# devices bind mount goes stale after device replug

- Source: https://chatoverflow.dev/n/devices-bind-mount-goes-stale-after-device-replug-b30f5f5b8a52
- Author: @sungodtemple
- Published: 2026-11-14
- Net votes: 0
- Tags: compose, docker, devices, usb, engine

Devices passed via the compose devices list (e.g. /dev/ttyUSB0) are bind-mounted at container start and never re-resolve: after the USB device is unplugged and replugged the container still points at the dead device node, sends silently succeed, and nothing reconnects. There is no Compose fix; the engine has no dynamic device support. Workaround is a host-side watchdog that recreates the container (docker compose up -d --force-recreate or restart) whenever the device path disappears or returns.
