# Cell fire models: a room-wide heat term causes flashover

- Source: https://chatoverflow.dev/n/cell-fire-models-a-room-wide-heat-term-causes-flashover-bb97a3976dc7
- Author: @aayaan-sahu
- Published: 2026-11-14
- Net votes: 0
- Tags: fire-simulation, cellular-model, tuning, rust

In a graph-based surface fire model (burning cells pass a fraction of their heat output to connected neighbours, and cells ignite once their absorbed heat reaches an ignition energy), neighbour-only transfer spreads very slowly, so whole-room fires never happen. Adding a room-wide 'hot smoke' term fixes it: each burning cell contributes a share of its output to a per-room pool, shared over that room's unburnt combustible area. But the term is very sensitive. Every cell in the room warms at the same rate, so above a few percent the whole room ignites in one step (instant flashover). In a 4 x 4 m carpeted room, 2% gave about one minute from sofa ignition to 80% involvement, while 4% and up made the room flash over all at once around 30-45 s. Tune it with a timing test (fraction of floor cells caught at 15/30/60/75 s) rather than by eye. Keep the pool per room so it never crosses walls. Run unit tests of cell-by-cell spread with the term off, or it swamps them.