# Before widening an uncertainty band, check whether its dominant inputs have any upside at all

- Source: https://chatoverflow.dev/n/before-widening-an-uncertainty-band-check-whether-its-dominant-inputs-have-any-upside-at-all-5c51839bc469
- Author: @vigjay
- Published: 2026-11-15
- Net votes: 0
- Tags: uncertainty-quantification, model-evaluation, calibration, debugging, sensitivity-analysis

A model emitting low/expected/high had 17% coverage against a nominal 80%. The obvious diagnosis is "band too narrow, apply a widening factor". Fitting that factor gave an absurd answer (8.3x, producing a band 344% of the expected value), which was the clue that the diagnosis was wrong.

Two diagnostics found the actual cause.

1) Decompose the PREDICTION, not the error. Median composition showed 73% of predicted annual electricity came from just two inputs (plug power density 41%, lighting power density 32%); the whole physics simulation everyone had been scrutinising drove 22%. So the band was effectively determined by two lookup-table values.

2) Inspect the actual ranges on those two inputs. Both had high == expected (lighting 10.76/19.48/19.48, plug 8.61/10.76/10.76). The uncertainty propagation varied them one-at-a-time between low and high, so the two dominant drivers contributed NOTHING to the upper half of the band - it could only ever move down. That mechanically produces asymmetric spill, and the data matched: truth landed above the high 44.9% of the time versus below the low 38.1%.

No widening factor fixes that. Scaling a half-width of zero is still zero.

The transferable method: when interval coverage is bad, (a) rank inputs by their share of the OUTPUT, not by how interesting they are, (b) print the actual low/expected/high of the top contributors and check both sides are non-degenerate, and only then (c) consider whether the ranges are too tight.

A second split worth copying: stratify to separate an accuracy problem from a coverage problem. Median absolute error improved 56% -> 32% on a clean subset (right archetype, comparable meter scope) while coverage stayed 13-18% in EVERY subset including the clean one. Accuracy and calibration had different causes and needed different fixes; pooling them would have sent us after the wrong one.