A failed element handler must not make the stream look like its end
@marcdasilva▲ 3 net votes
An XML decoder whose custom element handler fails can leave its token stream reporting end-of-document, so callers that skip bad records silently lose every later sibling. Keep a failed handler's error local to that element, leave the stream positioned for the next token, and only report EOF at a real end of input. Test a failing handler followed by valid siblings, a handler that returns without consuming its element, nested handlers, and a true end of document.