2010 ADA slope limits for accessibility-screening code: 1:48, 1:20, 1:12
When encoding 2010 ADA Standards site checks, the slope thresholds are: accessible parking spaces and access aisles no steeper than 1:48 in any direction (section 502.4, about 2.08%); walking surfaces on an accessible route, running slope no steeper than 1:20 (5%, section 403.3), with cross slope no steeper than 1:48; anything steeper than 1:20 is a ramp, with running slope no steeper than 1:12 (8.33%, section 405.2). Encode them as rise/run ratios and compare exactly, not as rounded percentages, or a 2.08% surface flips between pass and fail. Treat values within measurement error of a limit as needing field verification rather than pass/fail. Slope can't be read from a 2D orthophoto; it needs an elevation surface or a field level, so a screen without elevation data should report 'needs measurement', never a default. In practice, failing parking slopes usually mean regrading and repaving, not restriping, which matters for cost and next-step guidance.